Metrologic Instruments ARGUSSCANTM MS7220 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Barcodeleser Metrologic Instruments ARGUSSCANTM MS7220 herunter. Metrologic Instruments ARGUSSCANTM MS7220 User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Installation and User’s Guide

METROLOGIC INSTRUMENTS, INC. MS7220 ArgusSCAN™ PresentationLaser ScannerInstallation and User’s Guide

Seite 2

6Figure 2: OCIA, Interface poweredby the host deviceOCIAINSTALLATION FOR OCIA INTERFACE (CONTINUED)To power the unit from the host device:(For OCIA on

Seite 3 - LOCATIONS

7Figure 3: Keyboard WedgeInterfacesKeyboard WedgeINSTALLATION FOR KEYBOARD WEDGE INTERFACE1. Follow the “Getting Started” steps onpage 3.2. Turn off

Seite 4 - TABLE OF CONTENTS

8Figure 4: Stand-AloneKeyboard InterfaceStand-AloneKeyboardINSTALLATION FOR STAND-ALONE KEYBOARD INTERFACE1. Follow the “Getting Started” steps on pa

Seite 5 - SCANNER AND ACCESSORIES

9Figure 5: RS232 orLight Pen InterfaceRS232orLight PenINSTALLATION FOR RS232 OR LIGHT PEN INTERFACES1. Follow the “Getting Started” steps onpage 3.2

Seite 6

10INSTALLATION FOR RS232 OR LIGHT PEN INTERFACESStep 10, page 9 continued.For RS232 Communication:Scan 1st ³999998Recall DefaultsScan 2nd ³415554Ena

Seite 7 - GETTING STARTED

11INSTALLATION OF AN AUXILIARY SCANNER1. Turn off the host system.2. Connect the round end of the PowerLink RS232 AUX cable[ MLPN 54-54667A ] to the

Seite 8

12INSTALLATION OF AN AUXILIARY SCANNER11. Configure the auxiliary scanner to send formatted data to the MS7220.Normal slave mode operation will only r

Seite 9 - Figure 1: OCIA Interface

13SCANNER PARTSn Output Windowo Red LEDp Green LEDq Speakerr Side Covers Cable Doort Cable Jack Coveru Horizontal Mount Basev Multi-Function Button(

Seite 10 - For OCIA only)

14THE MULTI-FUNCTION BUTTONCHANGING THE BEEPER TONEA Short (<3 second) depression and thebeeper tone will change. The new tone willbe heard, follo

Seite 11 - Keyboard Wedge

15AUDIBLE INDICATORSWhen the MS7220 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight set

Seite 13 - Figure 5: RS232 or

16FAILURE MODESFlashing Green and One Razzberry ToneThis indicates the scanner has experienced a lasersubsystem failure. Return the unit for repair a

Seite 14 - Step 10, page 9 continued

17VISUAL INDICATORSThere is a red LED and a green LED on the front of the MS7220. When thescanner is on, the flashing or constant illumination of the

Seite 15 - Continued on page 12

18LABELSEach scanner has a label on the back of the unit. The label containsinformation such as the model number, date of manufacture, and the serialn

Seite 16 - Enable Aux Port

19DEPTH OF FIELD SPECIFICATIONS (BASED ON 100% UPC BAR CODES)Depth of Field (default)Figure 10: Top View of Depth of FieldFigure 11: Side View of Dept

Seite 17 - CANNER PARTS

20DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH(BASED ON 100% UPC BAR CODES)Depth of Field (Default)Figure 12: Top View of Depth of FieldSpecificat

Seite 18 - THE MULTI-FUNCTION BUTTON

21DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH(BASED ON 100% UPC BAR CODES)Depth of Field (Default)Figure 13: Side View of Depth of FieldSpecifica

Seite 19 - MLPN 00-02407 or 00-02561)

22TROUBLESHOOTING GUIDEThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to p

Seite 20 - FAILURE MODES

23TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe unit powersup, but doesnot scan and/orbeepScanning a particularsymbology tha

Seite 21 - VISUAL INDICATORS

24TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONScanner beepsat some barcodes and NOTfor others of thesame bar codesymbologyThe

Seite 22 - MAINTENANCE

25TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONAlphacharactersshow as lowercaseComputer is in CapsLock modeEnable Caps Lock det

Seite 23 - DEPTH OF FIELD SPECIFICATIONS

iiLOCATIONS CORPORATE HEADQUARTERS North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO90 Coles Road Tel: 856-228-8100Blackwoo

Seite 24 - Depth of Field (Default)

26TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONPower-up OKand scans OKbut does notcommunicateproperly to thehost.Com port notop

Seite 25

27RS232 DEMONSTRATION PROGRAMIf an RS232 scanner is not communicating with your IBM compatible PC,key in the following BASIC program to test that the

Seite 26 - TROUBLESHOOTING GUIDE

28APPLICATIONS AND PROTOCOLSThe model number on each scanner includes the scanner number andfactory default communications protocol.ScannerVersionIden

Seite 27

29DESIGN SPECIFICATIONSMS7220 DESIGN SPECIFICATIONSOPERATIONALLight Source: VLD 650 ± 10 nmLaser Power: 0.678 mW maximumDepth of Field: 0 mm to 215 mm

Seite 28

30DESIGN SPECIFICATIONSMS7220 DESIGN SPECIFICATIONSELECTRICALInput Voltage: 5.2VDC ± 0.25VPower: 1.9 WOperating Current: 360 mADC Transformers: Class

Seite 29

31DEFAULT SETTINGSMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from the factory

Seite 30 - MLPN 54-54667]

32DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBWDTS/NIXDORF*aNCR FaNCR SaPoll Light Pen SourceaBeeper Tone NormalaaaaaBee

Seite 31 - RS232 DEMONSTRATION PROGRAM

33DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBWConvert EAN-8 to EAN-13aa aaTransmit UPC-A NumberSystem*aaaaaTransmit UPC

Seite 32 - APPLICATIONS AND PROTOCOLS

34DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBWCarriage Return*aaLine Feed - disabled bydefault in KBW*aaTab PrefixaaTab

Seite 33 - DESIGN SPECIFICATIONS

35DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBWCoupon Code 128aaascode39aaProgrammable CodeLengths7 avail.aaaaaProgramma

Seite 34

iiiTABLE OF CONTENTSIntroduction...1Scanner and Acces

Seite 35 - DEFAULT SETTINGS

36DEFAULT SETTINGS (CONTINUED)Default settings for “Aux” interfaceThe slave scanner and the MS7220 always communicate via RS232. Datais relayed to th

Seite 36 - DEFAULT SETTINGS (CONTINUED)

37MS7220 STANDS Vertical Stand Kit [ MLPN 46-46405 ]See page 38 for installation instructions.Kit Includes:a. #8 x 1 round head wood screw [ MLPN 18-

Seite 37

38MS7220 STANDSVertical Stand Installation [ MLPN 46-46405 ]Remove the three screwssecuring the cable cover to theunit and slide it up and off thescan

Seite 38

39MS7220 STANDSOptional Flexible Stand Installation [ MLPN 46-46404 ]Remove the three screwssecuring the cable cover to theunit and slide it up and of

Seite 39

40SCANNER AND CABLE TERMINATIONSScanner Pinout ConnectionsThe MS7220 scanner interfaces terminate to 10-pin modular jacks locatedon the back of the un

Seite 40

41SCANNER AND CABLE TERMINATIONS (CONTINUED)MS7220Auxilary Port RS232 IN OnlyPin Function1 Ground2 RS-232 Receive Input3 RS-232 Transmit Output4RTS in

Seite 41 - MS7220 STANDS

42SCANNER AND CABLE TERMINATIONS (CONTINUED)Cable Connector ConfigurationThe PowerLink cable is terminated with a 5-pin DIN female connectoron one end

Seite 42 - MLPN 46-46405 ]

43LIMITED WARRANTYThe MS7220 scanners are manufactured by Metrologic at its Blackwood, New Jersey,U.S.A. facility. The MS7220 scanners have a two (2)

Seite 43 - MLPN 46-46404 ]

44NOTICESNoticeThis equipment has been tested and found to comply with limits for a Class A digital device,pursuant to Part 15 of the FCC Rules. Thes

Seite 44 - Scanner Pinout Connections

45NOTICES (CONTINUED)European StandardWarningThis is a class A product. In a domestic environment this product may cause radiointerference in which c

Seite 45 - Powerlink Cable

1INTRODUCTIONArgusScan™ is an aggressive, omnidirectional laser barcode scanner idealfor retail, convenience, liquor, and specialty store applications

Seite 46 - Cable Connector Configuration

46INDEX AAccessories ...1Adapter ...2, 42Audible...15Auto

Seite 48

April 2002Printed in USA 00- 02554A

Seite 49 - NOTICES (CONTINUED)

2SCANNER AND ACCESSORIES (CONTINUED)The following items are dependent on the type of MS7220 Kit ordered. Some items may not be included in your kit.•

Seite 50 - INDEX

3GETTING STARTEDTools needed:• Phillips head screwdriver • ¼”-20 wrench• Drill with a #39 drill bit (drill for hard-mount installation only)Slide

Seite 51

4GETTING STARTEDSee the “MS7220 Stands” section of this guide for additional information on the vertical[ MLPN 46-46405 ] and flexible [ MLPN 46-46406

Seite 52 - 00- 02554A

5Figure 1: OCIA InterfaceOCIAINSTALLATION FOR OCIA INTERFACETo power the unit with an external power supply:1. Follow the “Getting Started” steps onp

Kommentare zu diesen Handbüchern